Thursday, August 21, 2014
Two Zone Burglar Alarm
Descrition
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiHjjUjRHYoogjKaeWrsF3k0eQ2E8DjV1CfY0oGXRMcyfVr6_Pj-ncVhnKmDLxlv-qx_gH0WzVaVIZ_fExhPl0LZIbZNvanbXLBbBrvfwnDJP95lMJ68CYsr2NcFuehnBkjIpjRqnkf8IK3/s320/two-zone-burglar-alarm1.jpg)
This is a two-zone alarm - with automatic exit, entry and siren cut-off timers. It can be triggered by the usual types of normally-closed input devices - such as magnetic reed contacts - foil tape - PIRs etc. Ive used a 12-volt supply in the diagram - but the schema will work at anything from 9 to 15-volts. All you need do is select a siren, buzzer and relay to suit the voltage you want to use.
Schematic Diagram
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgeG3F0wmw0Iu8BNQCB2pmUHmExApgS5BrpyJAm6-2N2vc_DVWBZK0zmzj2iZZwWtTO7g9vuExv3SIV4zCG77FdyazezaVG9ob_DLWK22yOVupxT8KdfvgB1q2ReDd-GIEB3KQ8NQJ2pSBJ/s320/two-zone-burglar-alarm2.png)
When you move Sw1 to the Set position - you have about 30 seconds to leave the building. If you re-enter through the Exit/Entry zone - the buzzer will sound - and youll have about 30 seconds to switch the alarm off. The Instant zone has no entry delay. Anyone entering through the Instant zone - will sound the siren immediately.
About ten minutes after the normally-closed loops have been restored - the siren will switch off - and the alarm will return to standby mode. It can then be re-activated by a subsequent intruder. If you dont want the siren to sound a second time - add the One-Time-Only Module. It forces the siren to switch off after the first ten minutes. And it prevents the alarm from activating a second time. This module has other uses - so its worth a look.
The various timing components are listed in the diagram. If you want to change the length of any of the delays - change the value of the capacitor and/or the resistor shown. Increasing the value of either - will increases the delay. And reducing the value of either - will shorten the delay.